Lifetime Connectivity

RADIAFLEX Radiating Cables - size 1/2"

Filters

Size 1/2
Cable Type RLKW - RLK - RLKU - RCF - RLKAX
Jacket CPR, EN50575:2017 classified cable - CPR, EN50575:2014 + A1:2016 classified cable - JFL - JFN - CPR, EN50575 classified cable
Jacket Color Standard Black, other colors on request
Jacket Description Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier tape above outer conductor for lowest cable loss - Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin - Halogen free, non corrosive, flame retardant, low smoke, polyolefin
Jacket Testing Methods Test methods for fire behaviour of cable : - IEC 60754-1/-2 smoke emission: halogen free, non corrosive - IEC 61034 low smoke - IEC 60332-1 flame retardant - IEC 60332-3-24 fire retardant - UL1666, ASTM E 662, NES711 and NES713 - CPR: EN50575:2017 class Cca s1 do a1 - CPR: EN50575:2017 class B2ca s1a d0 a1 - IEC 60754-1/-2 smoke emission: halogen free, non corrosive - IEC 61034 low smoke - IEC 60332-1 flame retardant - IEC 60332-3-24 fire retardant - UL1666, ASTM E 662, NES711 and NES713 - CPR : EN50575:2014 + A1:2016 class B2ca s1a do a1 - CPR: EN50575:2014 + A1:2016 class B2ca s1a do a1 - CPR: EN50575:2014 + A1:2016 class B2ca s1a d0 a1 - CPR: EN50575:2014 + A1:2016 classified cable, class B2ca s1a do a1 - NFPA130 (ed. 2014) Ch.12 (NFPA70) via UL-1685/FT4/IEEE1202 - UL1666, ASTM E 662, NES711, NES713 and NFPA130 - IEC 60754-1/-2 smoke emission, halogen free, non corrosive - EN50575:2014 + A1:2016 (Hannover production) class Cca s1a d1 a1
Loading products

RLKW12-50CPR

Size
1/2
Impedance - Number
50
Impedance - Tolerance
2
Jacket
CPR, EN50575:2014 + A1:2016 classified cable
Jacket Description
Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier tape above outer conductor for lowest cable loss
Slot Design
Groups of vertical slots at short intervals
Frequency Selection
600
900
1800/1900
Request quote

RLKW12-50JFLA

Size
1/2
Impedance - Number
50
Impedance - Tolerance
2
Jacket
JFL
Jacket Description
Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier tape above outer conductor for lowest cable loss
Slot Design
Groups of vertical slots at short intervals
Frequency Selection
600
900
1800/1900
Request quote

RLK12-50JFNA

Size
1/2
Impedance - Number
50
Impedance - Tolerance
2
Jacket
JFN
Jacket Description
Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin
Slot Design
Groups of vertical slots at short intervals
Frequency Selection
600
900
Request quote

RLKU12-50JFNA

Size
1/2
Impedance - Number
50
Impedance - Tolerance
2
Jacket
JFN
Jacket Description
Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin
Slot Design
Groups of vertical slots at short intervals
Frequency Selection
600
900
1800/1900
2200
2400
2500
2700
Request quote

RLKU12-50CPR

Size
1/2
Impedance - Number
50
Impedance - Tolerance
2
Jacket
CPR, EN50575 classified cable
Jacket Description
Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier tape above outer conductor for lowest cable loss
Slot Design
Groups of vertical slots at short intervals
Frequency Selection
600
900
1800/1900
2200
2400
2500
2700
Request quote

RLK12-50CPR

Size
1/2
Impedance - Number
50
Impedance - Tolerance
2
Jacket
CPR, EN50575:2014 + A1:2016 classified cable
Jacket Description
Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier tape above outer conductor for lowest cable loss
Slot Design
Groups of vertical slots at short intervals
Frequency Selection
600
900
Request quote

RLK12-50JFLA

Size
1/2
Impedance - Number
50
Impedance - Tolerance
2
Jacket
JFL
Jacket Description
Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier tape above outer conductor for lowest cable loss
Slot Design
Groups of vertical slots at short intervals
Frequency Selection
600
900
Request quote

RLKU12-50JFLA

Size
1/2
Impedance - Number
50
Impedance - Tolerance
2
Jacket
JFL
Jacket Description
Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin + flame barrier tape above outer conductor for lowest cable loss
Slot Design
Groups of vertical slots at short intervals
Frequency Selection
600
900
1800/1900
2200
2400
2500
2700
Request quote

RCF12-50JFN

Size
1/2
Impedance - Number
50
Impedance - Tolerance
2
Jacket
JFN
Jacket Color
Standard Black, other colors on request
Jacket Description
Halogen free, non corrosive, flame retardant, low smoke, polyolefin
Slot Design
Milled (Two-Row)
Frequency Selection
600
900
1800/1900
2200
2400
2500
2700
6000
Request quote

RLKAX12-50JFNA

Size
1/2
Impedance - Number
50
Impedance - Tolerance
2
Jacket
JFN
Jacket Description
Halogen free, non corrosive, flame and fire retardant, low smoke, polyolefin
Slot Design
Groups of vertical slots at short intervals
Frequency Selection
2400
2600
3500
3800
4200
4900
5800
7000
Request quote