Lifetime Connectivity

HA-FODC-ALBB-04-XX
HYBRIFLEX® Hybrid Trunk Cable, Single-Mode Fiber, 4 mm² Power Cable

Rev : B | Rev date : 11 Dec 2025

RFS' HYBRIFLEX™cabling solution for Remote Radio Head (RRU) combines optical fiber and DC power for RRUs in a single lightweight aluminum corrugated cable, making it the world’s most innovative solution for RRH deployments. It was developed to reduce installation complexity and cost at Cellular sites.

HYBRIFLEX™cabling solutions allows mobile operators deploying RRH architecture to standardize RRH installation process and eliminates the need for and the cost of cable grounding.

The HYBRIFLEX™ Jumper is part of the cabling solution for RRU’s. It consists of an armored part of length XX, a breakout part to the RRU and a breakout part to the Distribution Box. The breakout part to the RRU is outdoor ready and sealed according to IP68. The breakout part to the Distribution Box is suitable to be installed to the RFS Distribution Box DB-T1-4Z-8B-0Z.

This Jumper cable is suitable for Ericsson RRUs. The Jumper cables can be ordered in 1m, 2m, 3m, 4m and 5m armored length.

 

Feature / Benefits

  •  Aluminum corrugated armor with outstanding bending characteristics

Minimizes installation time and enables mechanical protection and shielding

  • Build in Animal Protection

Improves the reliability of the installation

  • Outer conductor grounding

Eliminates typical grounding requirement and saves on installation costs

  • Lightweight solution and compact design

Decreases tower loads

  • Optical Fiber and power cables housed in single corrugated cable

Saves CAPEX by standardizing RRH cable installation and reducing installation equipments

  • Outdoor polyethylene jacket

Ensure long-lasting cable protection 

 

ha-fodc-albb-04-xx pic 1.jpg
Structure
Cable Type Hybrid Jumper
Mechanical Specifications
Outer Diameter Nominal 15.8mm (0.62in)
Minimum Bending Radius 70mm (3in)
Minimum Bending Radius 125mm (5in)
Tensile Strength 150N (33.7lb)
DC Power Cable Specifications
Number of DC Pairs 1
Maximum DC-Resistance Power Cable 4.95ohm/1000 m (1.51ohm/1000 ft)
Cross Section of Power Cable 4 (12)
Shielding provided by Al armor
DC Wire Jacket Material Polyethylene Black/ Blue
DC Wire Jacket Thickness 0.5mm (0.02in)
DC Cable Jacket UV stable black PE
DC Standards (Meets or Exceeds) IEC 60228
Cable Jacket
UV-Protection Individual and External Jacket Yes
Jacket Material UV stable black PE
Armor Specifications
Armor Type Corrugated Aluminum
Maximum DC-Resistance of Armor 2.78ohm/1000 m (0ohm/1000 ft)
Copper Equivalent Cross Section of Armor 8.4 (8)
Diameter Corrugated Armor 13.8mm (0.54in)
F/O Cable Specifications
F/O Cable Type Tight Buffer, Single Mode
Number of F/O Pairs 2
Core/Clad 9 /125
Secondary Protection Nominal 900µm (0.036in)
F/O Standards (Meets or Exceeds) ITU-T G.657.A
Loss (db) Wavelength (nm)
1 1310
1 1550
Fiber Termination End 1 FULLAXS for Ericsson RRUs
Fiber Termination End 2 LC Connector
Testing and Environmental
Storage Temperature -40°C to 70°C (-40°F to 158°F)
Operation Temperature -40°C to 65°C (-40°F to 149°F)
Installation Temperature -20°C to 65°C (-4°F to 149°F)
Additional Assemblies
Length Model Name
Length Model Name
1 m HA-FODC-ALBB-04-01
2 m HA-FODC-ALBB-04-02
3 m HA-FODC-ALBB-04-03
4 m HA-FODC-ALBB-04-04
5 m HA-FODC-ALBB-04-05